It is a common misbelief that fire systems need to be down for more than four consecutive hours prior to the implementation of a fire watch. Requirements to these regulations will vary from jurisdiction to jurisdiction as well as authorities having jurisdiction, or AHJs. In either situation, the fire department must be notified. Water-based fire protection systems need to be down for 10 hours or longer in a 24-hour timeframe. The NFPA requires a fire watch to be implemented if a system is down for more than four hours in a 24-hour timeframe. It is also required to institute a fire watch despite the nature of the impairment.

However, a fire watch needs to be instituted any time the fire system or part of the system cannot properly operate as it should. Interestingly, NFPA standards do not specify how much of the fire protection system needs to be compromised in order for a fire watch to be instituted. Water storage tanks and underground fire service mains.Sprinkler systems, including water spray, mist, and foam-water systems.Impairments to the following equipment within your system could cause a required fire watch: The NFPA 72 considers a system impairment as any “abnormal condition” that prevents the system or part of the system from functioning properly.
Firewatch california code#
This code also covers preplanned issues with the system that take effect when the system is purposely turned off for open flame operations like welding, or when the system is purposely disconnected to allow for testing and maintenance. Protecting the public from fire dangers and other circumstances that puts lives at stakeįire systems can fail to operate due to interruption in the system’s water supply, ruptured or frozen pipes, general equipment failure, or other issues that are found during a regular system inspection.Notifying both the fire department and building occupants in the event of a fire emergency.The information that follows in this guide will help you to understand what fire watches are, what they involve, and when they need to be instituted, as well as the options provided to building owners when running a fire watch.Ĭhapter three of the LSC states that a fire watch is the delegation of one or more people with the tasks of:

Whether due to mechanical, electrical or other type of failure, if your fire alarm or sprinkler system have become unreliable or incapacitated, you most likely need a fire watch on-site in order to avoid fines, liability and potential losses both in assets and human lives should there be an actual fire emergency. In fact, according to Annex A of the NFPA 72 Fire Alarm and Signaling Code, a fire watch is needed in all instances where a fire alarm system is compromised.
Firewatch california how to#
This regulation also lists the requirements for how to quickly and effectively take care of sprinkler system issues. The LSC requires anyone with a fire alarm system and water sprinkler system to respond to any hindrances in their fire protection system per Chapter 15 of the NFPA 25 Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems. Any building that has a sprinkler and/or fire alarm system may be required by the National Fire Protection Association (NFPA) 101 Life Safety Code (LSC) to institute a fire watch in the event that one or both of those systems fail to correctly function as designed.